{"product_id":"standard-leak-hole-standard-calibration-leak","title":"Standard Leak Hole (Standard Calibration Leak)","description":"\u003cdiv class=\"fgt-product-desc\"\u003e\n\n  \u003cp class=\"fgt-lead\"\u003eA Standard Leak Hole (Standard Calibration Leak) is a precision-drilled or micro-channel reference component used to verify the measurement accuracy and sensitivity of your leak test instruments. Without a calibrated leak reference, you cannot confirm that your tester is detecting what it claims to detect.\u003c\/p\u003e\n\n  \u003ch2\u003eWhat It Does\u003c\/h2\u003e\n  \u003cp\u003eEach Standard Leak Hole produces a stable, known, traceable leak rate under defined pressure conditions. When connected to your leak tester, it allows you to verify that the instrument responds correctly to a specific leak value — confirming the instrument is within calibration and that your test program thresholds are set correctly. This is a mandatory step in ISO- and IATF-compliant test line validation.\u003c\/p\u003e\n\n  \u003ch2\u003eTypes Available\u003c\/h2\u003e\n  \u003ctable\u003e\n    \u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003eConstruction\u003c\/th\u003e\n\u003cth\u003eTypical Use\u003c\/th\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMicro-channel capillary\u003c\/td\u003e\n\u003ctd\u003ePrecisely drawn glass or metal capillary\u003c\/td\u003e\n\u003ctd\u003eVery low leak rates, medical and precision electronics\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMetal-flatten type\u003c\/td\u003e\n\u003ctd\u003eControlled deformation of metal tube\u003c\/td\u003e\n\u003ctd\u003eMid-range leak rates, automotive and industrial parts\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eLaser-drilled\u003c\/td\u003e\n\u003ctd\u003eLaser-ablated orifice in metal plate\u003c\/td\u003e\n\u003ctd\u003eHigh-precision, high-repeatability reference leaks\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2\u003eSpecifications\u003c\/h2\u003e\n  \u003ctable\u003e\n    \u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eLeak rate\u003c\/td\u003e\n\u003ctd\u003eCustomized to your specification (e.g., 0.5 ml\/min, 5 ml\/min, sccm equivalent)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±5% of nominal value\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCalibration certificate\u003c\/td\u003e\n\u003ctd\u003eThird-party traceable calibration certificate included\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eStandard 1\/8 NPT or customized port\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTraceability\u003c\/td\u003e\n\u003ctd\u003eFully traceable to national measurement standards\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2\u003eWhen You Need a Standard Leak Hole\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eInitial instrument setup:\u003c\/strong\u003e Confirm your tester detects at the required sensitivity before production begins\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePeriodic calibration checks:\u003c\/strong\u003e Validate instrument performance at defined intervals (daily, shift-start, or per quality plan)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProcess validation:\u003c\/strong\u003e Required documentation for PPAP, IATF 16949, ISO 13485, and similar quality programs\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eThreshold setting:\u003c\/strong\u003e Physically verify that your NG threshold actually catches the target leak rate\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCross-site consistency:\u003c\/strong\u003e Ensure multiple test stations or plants are measuring to the same standard\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2\u003eWhy Figurtech Standard Leak Holes?\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eThird-party certified:\u003c\/strong\u003e Every unit ships with a traceable calibration certificate — ready for audit documentation\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCustom leak rates:\u003c\/strong\u003e Specify exactly the leak value your process requires — not limited to catalog values\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMatched to your instruments:\u003c\/strong\u003e Designed and validated to work with LY, LD, LF, LG, LM, and LE series testers\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003cp\u003e\u003cem\u003eSpecify your required leak rate (ml\/min or sccm), test pressure, and connection type when ordering. Custom leak rates and connection geometries are available.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Figurtech","offers":[{"title":"Default Title","offer_id":48632667111680,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0830\/3493\/1456\/files\/Standard-Leak-Holes-Placeholder-02.jpg?v=1776932492","url":"https:\/\/www.figurtech.com\/products\/standard-leak-hole-standard-calibration-leak","provider":"Figurtech Leak Test Solution","version":"1.0","type":"link"}